Our products are all sent in discreet packaging.

Peritone EMG Biofeedback unit

Peritone EMG Biofeedback unit

NeuroTrac® Myoplus PRO

Clinical device delivering EMG, ETS and NMES. Has built in games for engagement with EMG function. 

$770.00
Availability: In stock
SKU
NMPRO

NeuroTrac® Myoplus is an all-in-one assessment and treatment tool.
It combines

  • EMG biofeedback
  • Electrical stimulation and
  • ETS ( EMG triggered stimulation) modes. ETS allows you to set the threshold at which stimulation is triggered - meaning the patient has to contract to a pre-set threshold before the stimulation phase starts,
    thus assisting in return to independent activation of the pelvic floor.
  • It can be used to assess electrical activity in the pelvic floor muscles, then switch to ETS or Stimulation mode for treatment - all in the one session. 

NeuroTrac® Myoplus is a Portable Desk Top device, supplied with a desk top stand.

  • EMG + Stimulation mode {Passive + Active}, EMG Triggered Stimulation, Muscle Stimulation and EMG Modes
  • Designed to be used for a wide range of Physiotherapy, Sports and Rehabilitation applications including Continence and Stroke treatment.
  • Custom programs enabling up to 5 phases to be set up in one program.
  • Optional Multilingual PC Database Software
  • Used as a learning tool with emphasis on improving treatment protocols using EMG and Neuromuscular Stimulation
  • Locks programmes and records Patient Home Compliance on a daily basis.
  • Portable, light and user friendly.

1. EMG

  • Single Channel
  • EMG Range: 0.2 to 2000 μV RMS (continuous)
  • Sensitivity: 0.l μV RMS
  • Accuracy: 4% of μV reading +/-0.3 μV at 200 Hz
  • Selectable Bandpass filter - 3db Bandwidth,
    • a. Wide: 18 Hz +/- 4 Hz to 370 Hz +/- 10% - Reading below 235 microvolts 10 Hz +/-3 Hz to 370 Hz +/- 10% - Readingabove 235 microvolts
    • b. Narrow: 100 Hz +/- 5% to 370 Hz +/- 10%
  • Notch filter: 50 Hz (Canada 60Hz) - 33 dbs (0. 1% accuracy)
  • Common Mode Rejection Ratio: 130 dbs Minimum @ 50 Hz
  • Battery: PP3 Alkaline
  • Work / Rest periods: 2-99 seconds
  • Number of Trials: 1-99

 

2. Neuromuscular Stimulation

  • Single Channel
  • Amplitude: 0-90 mA into 500 Ohm load - actual mA will tend to be less than indicated due to Electrode impedance: at 1000 Ohms load (Electrodes in poor condition) the maximum will be limited to 75 mA, at 1500 Ohms load the maximum will be limited to 50 mA.
  • Type: Constant current, maximum output voltage 70 Volts +5 / -10 Volts
  • Waveform: Symmetrical, rectangular, bi-phasic with net zero DC current
  • Pulse width selection: 50-450 μS (2% accuracy)
  • Pulse rate selection: 2-100 Hz (2% accuracy)
  • Work / Rest periods: 2-99 seconds
  • Time 1 - 99 minutes
  • Ramp up time: 0.1 - 9.9 seconds
  • Preset and user programmable treatment Programs
  • Automatic output shut off with detection of open electrode above 0.5 mA

USA CUSTOMERS PLEASE NOTE: Unfortunately US laws prevent us from supplying electrical devices to US customers. Orders placed from US addresses sadly have to be refunded, but with the loss of the charges imposed by our payment processing systems.

Specifications
Specifications

1. EMG

  • Single Channel
  • EMG Range: 0.2 to 2000 μV RMS (continuous)
  • Sensitivity: 0.l μV RMS
  • Accuracy: 4% of μV reading +/-0.3 μV at 200 Hz
  • Selectable Bandpass filter - 3db Bandwidth,
    • a. Wide: 18 Hz +/- 4 Hz to 370 Hz +/- 10% - Reading below 235 microvolts 10 Hz +/-3 Hz to 370 Hz +/- 10% - Readingabove 235 microvolts
    • b. Narrow: 100 Hz +/- 5% to 370 Hz +/- 10%
  • Notch filter: 50 Hz (Canada 60Hz) - 33 dbs (0. 1% accuracy)
  • Common Mode Rejection Ratio: 130 dbs Minimum @ 50 Hz
  • Battery: PP3 Alkaline
  • Work / Rest periods: 2-99 seconds
  • Number of Trials: 1-99

 

2. Neuromuscular Stimulation

  • Single Channel
  • Amplitude: 0-90 mA into 500 Ohm load - actual mA will tend to be less than indicated due to Electrode impedance: at 1000 Ohms load (Electrodes in poor condition) the maximum will be limited to 75 mA, at 1500 Ohms load the maximum will be limited to 50 mA.
  • Type: Constant current, maximum output voltage 70 Volts +5 / -10 Volts
  • Waveform: Symmetrical, rectangular, bi-phasic with net zero DC current
  • Pulse width selection: 50-450 μS (2% accuracy)
  • Pulse rate selection: 2-100 Hz (2% accuracy)
  • Work / Rest periods: 2-99 seconds
  • Time 1 - 99 minutes
  • Ramp up time: 0.1 - 9.9 seconds
  • Preset and user programmable treatment Programs
  • Automatic output shut off with detection of open electrode above 0.5 mA

Low battery indication at 7.4 volts +/- 0.2 volts and automatic shut off 4 minutes
after pressing last key, unless infra-red is turned on.
Note: Replace battery immediately.


Environmental Conditions for use:
+10 to +30 degrees Centigrade. 0-90% Humidity.
Environmental conditions for storage & transport:
-10 to +50 degrees Centigrade. 0-90% Humidity.
Physical Dimensions: Length 147 mm, Width 70 mm, Depth 28.9 mm
Weight
MyoPlus device: 0.13 Kg (without battaery)
PP3 Alkaline battery: about 0.04 Kg

No Related Posts

1. EMG

  • Single Channel
  • EMG Range: 0.2 to 2000 μV RMS (continuous)
  • Sensitivity: 0.l μV RMS
  • Accuracy: 4% of μV reading +/-0.3 μV at 200 Hz
  • Selectable Bandpass filter - 3db Bandwidth,
    • a. Wide: 18 Hz +/- 4 Hz to 370 Hz +/- 10% - Reading below 235 microvolts 10 Hz +/-3 Hz to 370 Hz +/- 10% - Readingabove 235 microvolts
    • b. Narrow: 100 Hz +/- 5% to 370 Hz +/- 10%
  • Notch filter: 50 Hz (Canada 60Hz) - 33 dbs (0. 1% accuracy)
  • Common Mode Rejection Ratio: 130 dbs Minimum @ 50 Hz
  • Battery: PP3 Alkaline
  • Work / Rest periods: 2-99 seconds
  • Number of Trials: 1-99

 

2. Neuromuscular Stimulation

  • Single Channel
  • Amplitude: 0-90 mA into 500 Ohm load - actual mA will tend to be less than indicated due to Electrode impedance: at 1000 Ohms load (Electrodes in poor condition) the maximum will be limited to 75 mA, at 1500 Ohms load the maximum will be limited to 50 mA.
  • Type: Constant current, maximum output voltage 70 Volts +5 / -10 Volts
  • Waveform: Symmetrical, rectangular, bi-phasic with net zero DC current
  • Pulse width selection: 50-450 μS (2% accuracy)
  • Pulse rate selection: 2-100 Hz (2% accuracy)
  • Work / Rest periods: 2-99 seconds
  • Time 1 - 99 minutes
  • Ramp up time: 0.1 - 9.9 seconds
  • Preset and user programmable treatment Programs
  • Automatic output shut off with detection of open electrode above 0.5 mA

Low battery indication at 7.4 volts +/- 0.2 volts and automatic shut off 4 minutes
after pressing last key, unless infra-red is turned on.
Note: Replace battery immediately.


Environmental Conditions for use:
+10 to +30 degrees Centigrade. 0-90% Humidity.
Environmental conditions for storage & transport:
-10 to +50 degrees Centigrade. 0-90% Humidity.
Physical Dimensions: Length 147 mm, Width 70 mm, Depth 28.9 mm
Weight
MyoPlus device: 0.13 Kg (without battaery)
PP3 Alkaline battery: about 0.04 Kg