Axelgaard PALS Clinical HYPOALLERGENIC adhesive electrodes (5x5cm square, 5x10cm rectangle) (PK4)
High quality hypoallergenic adhesive electrodes
PALS® Clinical
Designed for all EMS and TENS applications, PALS® Clinical is the most advanced in the PALS® electrode series and considered to be Axelgaard’s highest quality neurostimulation electrode.
- Patented stainless steel knit cloth provides optimum conductivity and conformity
- Hydrogel construction with exclusive impedance compensation system
- Enhances patient comfort during stimulation by dispersing current evenly across the electrode whilst eliminating stinging, edge biting, and hot spots.
- Oversized border is specially designed to facilitate ease of proper removal to further promote electrode durability
Featuring Axelgaard’s new skin friendly AmSeal®adhesive, which provides a superior bond.
The specialized blue DermaFlow® gel is formulated with a composition less likely to cause allergic reactions or skin sensitivity.*
- hypoallergenic
- antimicrobial
- latex free
- gentle enough for use on extremely sensitive skin
- designed to prevent smearing of the hydrogel outside the electrode area
- thick enough to adhere through body hair
* While DermaFlow is designed to be our most gentle to skin hydrogel yet, there is still a slight chance of a patient developing skin sensitivity as different people have different reactions.
How many times can the electrodes be used?
Number of uses depends entirely on the proper application, storage and care by the user.
The durability of the electrodes depends on the adhesiveness of the gel and that depends on keeping the gel
- clean
- hydrated
- free from foreign debris
Application:
Before each electrode application, skin must be cleaned with water and soap to remove any lotions, skin oils, make-up, and dead skin.
Any debris on the skin will be transferred to the gel of the electrode compromising the integrity of the gel's adhesiveness.
A clean surface is the most important factor in the number of applications for an electrode.
Removal
Always lift electrodes from the edge - not the leadwire.
Care
After use, if the electrode picks up small amounts of debris you may use a drop of water on your finger to gently rub the debris off the electrode.
They are designed for reuse by the same person provided there is proper care of the skin and the electrodes.
Risk of contamination increases with each application.
Every time an electrode is removed, it lifts off dirt and skin debris, which in turn becomes absorbed into the gel.
To maintain optimal hygiene change electrodes when they become contaminated in this fashion.
Most important to the care of the electrode is applying it to a clean surface with each use.
Storage
After every use the electrode must be returned to the "ON" side of the Mylar liner and placed in the original, re-sealable package to prevent loss of moisture.
Electrodes should be stored at a temperature between 5°-27°C
Do not
- store in freezer/refrigerator
- leave in extreme heat
- submerge in water
- leave outside of the package
- use soap, alcohol or scrub with abrasive material
- Do not share your electrodes with anyone else, they are single patient use only
Made in the USA